All Major Credit Cards Accepted
|
E-mail: nni_inc@hotmail.com
Toll Free:
1-877-NNI-FIRE
(1-877-664-3473)
| |
|
Fire Hydrant Meters |
Sportster FHZ Fire Hydrant Meter
|
3” Zenner Model FHZ
Sportster Model FHZ Hydrant Meters are designed to measure a wide variety of cold potable water flows from fire hydrants where flows are in one direction.These Hydrant Meters are light weight portable units designed for temporary installations.
OPERATION:
Water flows through the turbine section causing the rotor to turn proportionately to the quantity of water flowing through the meter. A drive magnet transmits the motion of the rotor to a driven magnet located within the hermetically sealed register. The magnet is connected to a gear train which translates the rotations into volume totalization displayed on the register dial face. The only moving parts in the meter are the rotor assembly and vertical shaft .
CONSTRUCTION:
Sportster Hydrant Meters consist of several basic components: light weight aluminum main case, aluminum cover plate, turbine type measuring element assembly, sealed register, stainless steel hardware, brass lid assembly, stainless steel handles, brass swivel and brass nipple. The measuring element assembly includes the rotor assembly, vertical shaft and a calibration vane which eliminates the need for calibration change gears.
COMPLIANCE:
Sportster Hydrant Meters are tested and comply with AWWA C701 Class II performance standards.
STRAINERS:
Sportster Hydrant Meters come with an inlet strainer built into the Swivel.
OPTIONS:
Gate Valves, check valves, reduced pressure Backflow Preventers, locking devices, special order connections, “add-on” restrictor plates and stands.
3” Model FHZ30SUS: 3" Hydrant Meter with Stainless Steel Double Handles, 2-1/2" FNST Swivel x 2-1/2" MNST, Gallon. (Available in Cubic Ft. read also)
$955.95
3” Model FHZ30SUS-V: 3" Hydrant Meter with Stainless Steel Double Handles, 2-1/2" FNST Swivel x 2-1/2" MNST, Gallon with 2-1/2" Gate Valve (Available in Cubic Ft. read also)
$1245.95
Spec Sheet
|
FHC Fire Hydrant Meter
|
3” Zenner Model FHC
California Model FHC Hydrant Meters are designed to measure a wide variety of cold potable water flows from fire hydrants where flows are in one direction. These Meters are light weight portable units designed for temporary installations.
OPERATION:
Water flows through the turbine section causing the rotor to turn proportionately to the quantity of water flowing through the meter. A drive magnet transmits the motion of the rotor to a driven magnet located within the hermetically sealed register. The magnet is connected to a gear train which translates the rotations into volume totalization displayed on the register dial face. The only moving parts in the meter are the rotor assembly and vertical shaft .
CONSTRUCTION:
California Hydrant Meters consist of several basic components: light weight aluminum main case, turbine type measuring element assembly, sealed register, aluminum cover plate, stainless steel hardware, brass lid assembly, aluminum or brass swivel and nipple, aluminum or stainless steel handles, etc. The measuring element assembly includes the rotor assembly, vertical shaft and a calibration vane which eliminates the need for calibration change gears.
RESTRICTOR PLATE:
The standard California Hydrant Meter (FHC25) has a permanent flow restrictor machined into the main case. This limits the maximum flow of water through the meter and provides protection for the measuring element from being overrun when the meter discharges. The restrictor plate may be enlarged for specific utility requirements.
CONFORMANCE: California Hydrant Meters are tested and comply with AWWA C701 Class II performance standards.
STRAINERS:
California Hydrant Meters come with an inlet strainer built into the Swivel.
3” Model FHC25GAL: Hydrant Meter with Stainless Steel Double Handles, 2-1/2" FNST Swivel x 2-1/2" MNST, Gallon. (Available in Cubic Ft. read also)
$998.95
Spec Sheet
|
FHP Performance Hydrant Meter
3" Model FHP25DUS
|
3” Performance Model FHP
INTRODUCTION: ZENNER PERFORMANCE Hydrant Meters are designed to measure a wide variety of cold potable water flows from fire hydrants where flows are in one direction. These Meters are light weight portable units designed for temporary installations.
OPERATION: Water flows through the turbine section causing the rotor to turn proportionately to the quantity of water flowing through the meter. A drive magnet transmits the motion of the rotor to a driven magnet located within the hermetically sealed register. The magnet is connected to a gear train which translates the rotations into volume totalization displayed on the register dial face. The only moving parts in the meter are the rotor assembly and vertical shaft .
CONSTRUCTION: ZENNER PERFORMANCE Hydrant Meters consist of several basic components: light weight aluminum main case, turbine type measuring element assembly, sealed register, aluminum cover plate, stainless steel hardware, brass lid assembly, aluminum or brass swivel and nipple, aluminum or stainless steel handles, etc. The measuring element assembly includes the rotor assembly, vertical shaft and a calibration vane which eliminates the need for calibration change gears.
RESTRICTOR PLATE: The standard ZENNER PERFORMANCE Hydrant Meter (FHP25) has a permanent flow restrictor machined into the main case. This limits the maximum flow of water through the meter and provides protection for the measuring element from being overrun when the meter discharges. The restrictor plate may be enlarged for specific utility requirements.
MAINTENANCE: ZENNER PERFORMANCE Hydrant Meters are engineered and manufactured to provide long-term service and operate virtually maintenance free. If maintenance is necessary the measuring element can be removed from the main case. CONFORMANCE:
ZENNER PERFORMANCE Hydrant Meters are tested and comply with AWWA C701 Class II performance standards.
STRAINERS: ZENNER PERFORMANCE Hydrant Meters come standard with a large built-in 54 square inch strainer.
CONNECTIONS: ZENNER PERFORMANCE Hydrant Meters are typically configured with bronze connections, although aluminum connections are available.
3” Model FHP25DUS: Performance Hydrant Meter with Aluminum Double Handles, 2-1/2" FNST Swivel x 2-1/2" MNST, Gallon. (Available in Cubic Ft. read also)
$1395.95
SpecSheet
|
FHH High Flow Hydrant Meter
4" Model FHH30DUS
4" Model FHH40SUS
|
4” High Flow Model FHH
INTRODUCTION: ZENNER High Flow Hydrant Meters are light weight portable units. They are designed to measure a wide variety of cold potable water flows from fire hydrants where flows are in one direction. These water meters have a 4” turbine measuring element for use in applications where high flows are expected.
OPERATION: Water flows through the turbine section causing the rotor to turn proportionately to the quantity of water flowing through the meter. A drive magnet transmits the motion of the rotor to a driven magnet located within the hermetically sealed register. The magnet is connected to a gear train which translates the rotations into volume totalization displayed on the register dial face. The only moving parts in the meter are the rotor assembly and vertical shaft.
CONSTRUCTION: ZENNER High Flow Hydrant Meters consist of several basic components: light weight aluminum main case, turbine type measuring element assembly, sealed register, aluminum cover plate, stainless steel hardware, brass lid assembly, aluminum or brass swivel and nipple, aluminum or stainless steel handles, etc. The measuring element assembly includes the rotor assembly, vertical shaft and a calibration vane which eliminates the need for calibration change gears.
MAINTENANCE: ZENNER High Flow Hydrant Meters are engineered and manufactured to provide long term service and operate virtually maintenance free. If maintenance is necessary the measuring element can be removed from the main case.
CONFORMANCE: ZENNER High Flow Hydrant Meters are tested and comply with AWWA C701 Class II performance standards.
STRAINERS: ZENNER High Flow Hydrant Meters come standard with a large built-in 54 square inch strainer.
CONNECTIONS: ZENNER High Flow Hydrant Meter Model FHH30 is typically configured with bronze connections, although aluminum connections are available. The FHH40 and FHH45 Models are typically configured with aluminum connections, although brass connections are available.
OPTIONS: Gate Valves, locking devices, special order connections, aluminum double handles, stainless steel double handles and locking single handles.
4” Model FHH30DUS: High Flow Hydrant Meter with Aluminum Double Handles, 3 x 3 Housing/4" Bore, 2-1/2" FNST Swivel x 2-1/2" MNST, Gallon. (Available in Cubic Ft. read also)
$1695.50
4” Model FHH40SUS: High Flow Hydrant Meter with Stainless Steel Double Handles, 3 x 3 Housing/4" Bore, 4" FNST Swivel x 4" MNST, Gallon. (Available in Cubic Ft. read also)
$2125.95
Spec Sheet
|
FHD Fire Hydrant Backflow Meter with RPZ
|
3” Dual Check RPZ Model FHD
FHD Fire Hydrant Backflow Meters, with built-in dual check valves and RPZ dump valve
They are designed to measure a wide variety of cold potable water flows from fire hydrants where flows are in one direction.
FHD Meters are light weight portable units designed for temporary installations. The built-in dual check valves help provide a practical solution to help prevent backflow into the primary water source. The RPZ (Reduced Pressure Zone) Dump Valve allows this assembly to dump to atmosphere when the check valves are fouled.
OPERATION:
Water flows through the turbine section causing the rotor to turn proportionately to the quantity of water flowing through the meter. A drive magnet transmits the motion of the rotor to a driven magnet located within the hermetically sealed register. The magnet is connected to a gear train which translates the rotations into volume totalization displayed on the register dial face.
CONSTRUCTION:
FHD Hydrant Meters consist of several basic components: light weight aluminum main case, turbine type measuring element assembly, sealed register, aluminum cover plate, stainless steel hardware, brass lid assembly, aluminum or brass swivel and nipple, aluminum or stainless steel handles, front and rear 3” check valves, RPZ Dump Valve and adjustable support stand. The measuring element assembly includes the rotor assembly, vertical shaft and a calibration vane which eliminates the need for calibration change gears.
MAINTENANCE:
FHD Meters are engineered and manufactured to provide long-term service and operate virtually maintenance free. If maintenance is necessary the measuring element can be removed from the main case. The 3” Check Valves and RPZ can be easily serviced.
COMPLIANCE:
FHD Hydrant Meters are tested and comply with AWWA C701 Class II performance standards.
STRAINERS:
FHD Hydrant Meters come with a built-in 54 square inch strainer after the first check valve and in front of the Turbine Measuring Element.
CONNECTIONS:
FHD Meters are typically configured with bronze fire hose connections, although aluminum connections are available.
OPTIONS:
Locking devices, special order connections, pistol grip handles, swivel with stainless steel strainer.
3” Model FHD30S**-RP
|
994BLT, 4000BLT Portable Hydrant Meter Backflow Preventer
|
Watts Model 994BLT or
Ames 4000BLT
Portable Hydrant Meter Backflow Preventers
Size(s): 2 1/2 in. FNPT x 3 in. MNPT
Description:
Ames Model 4000BLT or Watts Model 994BLT Portable Hydrant Meter Backflow Preventers prevent the reverse flow of polluted from entering into the potable water supply where flow is in one direction and the possibility of cross-connections exists, such as at a fire hydrant or other non-permanent installation. It consists of stainless steel body construction with stainless steel internal parts. Its portable, lightweight design provides long-term service with minimal maintenance. Series 4000BLT is ideal for use on existing hydrant meter hookups. Factory assembled and tested.
4000BLTSpecification Sheet ----------- 994BLT Specification Sheet
Model: 4000-BLT
Ordering Code 0690619
Model: 994BLT
Ordering Code 0437815
$4,975.80 |
994HMB, 6000HMB Fire Hydrant Backflow Meter
|
Watts Model 994HMB or
Ames 6000HMB
Portable Hydrant Meter Backflow Preventers with Meter
Size(s): 2 1/2 to NST x 3 in.
Description:
Ames Model 6000HMB or Watts Model 994HMB Portable Hydrant Meter Backflow Preventers prevent the reverse flow of polluted water from entering into the potable water supply where flow is in one direction and the possibility of cross-connections exists, such as at a fire hydrant or other non-permanent installation. It consists of a stainless steel body construction with stainless steel internal parts, meter housing, measuring element, and permanently sealed register to measure flow and protect the meter and backflow preventer from damage due to excessive flow. Series 994HMB meets AWWA C701 meter requirements and is ideal for use in existing hydrant meter hookups. Factory assembled and tested.
6000HMB Specification Sheet ___994HMB Specification Sheet
Model: 3 6000HMB-GPM
Ordering Code 0690618
Model: 3 994HMB-GPM
Ordering Code 0437808
Model: 3 6000HMB-CFM
Ordering Code 0692541
Model: 3 994HMB-CFM
Ordering Code 0437809
$6,995.50
|
FHD Fire Hydrant Meter Locks
|
INTRODUCTION:
ZENNER Fire Hydrant Meter Locks are designed to easily secure hydrant meters quickly and effectively. These unique hydrant locks allow utilities to “throw away the chains.” They are easy to install and keep hydrant meters safe from theft.
OPERATION:
ZENNER Fire Hydrant Meter Locks are easy to install. They are of a clam shell design which when closed and locked over the swivel, the hydrant meter may not be removed. The Universal Break-away model restricts access to the swivel while at the same time allowing for the hydrant meter to break-away at the swivel rather than damage the hydrant.
CONSTRUCTION:
ZENNER Fire Hydrant Meter Locks are made of cast aluminum.
OPTIONS:
ZENNER Fire Hydrant Meter Locks are designed to be used with either a Padlock or a Barrel Lock.
HYD-FHD-L: Model ZBHLP Zenner Breakaway Hydrant Lock, Designed for Padlock
$129.50
Data Sheet |
Also see Hydrant Testing Products at
|
E-mail: nni_inc@hotmail.com Phone: 305-687-3330